In our store, you will find both new and preowned data collectors for land surveying from some of the leading manufacturers of data collection equipment such as Carlson, Sokkia and JettCE. We are of course authorized dealers of such equipment so naturally, we also have all of the software available for your needs as well. As the premier dealer of Carlson Software for the state of South Carolina, we carry SurvCE, Carlson Survey and even software for your GPS and machine control needs.
JettCE
How do I do a cold (hard) reset on the JettCE?
1. Turn the unit off by pressing and holding thepower key for 8 seconds.
2. Press and release the power key again.
3. Press and hold the 1st and 3rd keys in the first
column of the keypad (A & I).
Note: This must be done immediately after releasing
the power button.
How do I do a warm (soft) reset on the JettCE?
Select Start | Programs | Warm Reboot.The JettCE acts slowly. What can i do?
The unit may be short of program memory or storagememory. Increase the amount of storage memory through
the System control in the Control Panel. You can also
delete any unnecessary files.
Is the JettCE ready for Bluetooth?
The JettCE does not have an internal Bt card when itis shipped, however the JettCE is Bt ready. In order
to activate Bt insert a Socket Bluetooth CF card
(www.socketcom.com) in the top Compact Flash slot of
the JettCE.
Allegro
How do I cold-reboot the system?
Restoring
the system on your Allegro restores the operating system to the factory default settings or the settings that were in place the last time you performed the Save System utility function. Any changes made to the control panel settings and registry key settings are removed. To restore the system on your Allegro, complete the following steps: |
1.
Press the On/Off key and the Shift key at the same time for 5 - 10 seconds. 2. Release the Shift key and On/Off key, at the same time, as soon as the Boot Menu appears. 3. Use the Arrows key to select the cold boot option and press Enter. |
How do I establish a first time ActiveSync connection using COM 1 or COM 2?
When
establishing a COM 1 or COM 2 connection between the Allegro and your desktop PC for the first time, complete the following steps: |
1.
Attach one end of the serial communication cable that was included with your Allegro (part number 12446) to the COM 1 or COM 2 port on your desktop PC. 2. Plug the other end of the communication cable into COM 1 or 2 on the Allegro. 3. Turn on the Allegro. 4. Tap the Start button on your Allegro and select Settings | Control Panel | Communications Properties. 5. Tap the PC Connection tab. At the bottom if the screen next to Connect using: is the COM port the Allegro is set on for an ActiveSync connection. 6. Tap the Change button to access the Change Connection screen if you are using a different communication port than the Connect using: port lists. 7. Tap on the arrow next to the Connect to desktop using: box to access a drop-down list. |
8.
Tap on the desired communicator port and baud rate in the drop-down box, and tap on the OK button. 9. Double-click on the ActiveSync icon on the desktop PC and Get Connected screen appears. 10. Click on the Next button and the Get Connected: Checking COM Ports screen appears. 11.A. If using COM 1, the Progress box of the Checking COM Ports screen says Looking for a Mobile device & Checking on COM Port 1, double-tap on the PC Link icon on your Allegro desktop. After tapping the PC Link icon on the Allegro desktop, a screen that says Connecting to Host is shown. If you are unsuccessful in your connection, try again. 11.B. If using COM 2, wait for the Progress box of the Checking COM Ports screen indicating Looking for a Mobile device & Checking on COM Port 1 to advance to Checking on COM Port 2, now double-tap on the PC Link icon on your Allegro desktop. Once connected, a connected system tray icon appears in the in the status box on the Taskbar. If the Allegro disconnects from the desktop PC, by choice or inadvertently, this icon disappears, letting you know the Allegro is not connected to the computer. |
How do I reboot the Allegro?
Resetting
the Windows CE registry on your Allegro initiates your operating system to reload. This process reloads all the drivers on your Allegro. To reset your Allegro, complete the following steps: |
1.
Press down and hold the On/Off key for 5 - 10 seconds. 2. Release the On/Off key when the Allegro turns off and then restarts. 3. Wait for the operating system to load.When the normal reboot fails, try a cold reboot. |
The software application I am running on the Allegro or the operating system on my Allegro is no longer responding. How do I fix this?
Occasionally,
software applications or the operating system may cease to respond, leaving the Allegro in a state where it cannot be used until the software application is closed or the operating system is active again. To check if it is a software application, or the operating system that is not responding on your Allegro, complete the following steps: |
1. Press
the Task Manager key (BLUE + Start key) on your Allegro, or by pressing the Alt key and the TAB right key simultaneously.If the Task Manager window opens, then the operating system is running and your application is what has stopped responding. 2. View all running applications from the Task Manager window. 3. Tap on any applications not responding in the Task Manager window so it is highlighted. 4. Tap on the End Task button to close the applications that are not responding. When this procedure fails, try a reboot. |